Talking about the vortex flowmeter to measure steam needs attention

Henan Bo Rui Instrument Co., Ltd. () specializing in the production and sales of electromagnetic flowmeters, vortex flowmeters and other flow meters, welcome new and old customers to negotiate, service hotline; 18638176136; more news: http://
Talking about the vortex flowmeter to measure steam needs attention

What should I pay attention to when measuring vortex flowmeter? What is the best way to measure steam installation by vortex flowmeter? Can vortex flowmeters be used for metering of steam trade settlements? The vortex flowmeters are evaluated for their measurement performance under single-phase flow conditions. There is currently no single-phase flowmeter for measuring the system variation of two-phase flow. However, the two-phase flow exists objectively, and its influence on flow measurement is unavoidable. Despite the difficulties, people are still trying to study the mechanism of its influence on flow measurement, and take corresponding countermeasures to improve the accuracy of flow measurement.


Difficulties in steam flow: During long-distance transportation, dry steam will partially condense due to heat loss, resulting in reduced steam dryness and wet steam. The gas-liquid two-phase flow structure in the horizontal pipe is related to the gas-liquid two-phase volume ratio and the flow velocity. In the steam pipe, since the volume ratio of the condensed water in the wet steam is small, the drain pipe drawn from the bottom of the horizontal pipe is made. , can receive a good hydrophobic effect. When the flow rate is particularly high, it will also behave as a circular flow, that is, there is a liquid film on the pipe wall, and the central part of the pipe is a gas core with droplets. Due to the influence of gravity during horizontal flow, the lower liquid film is higher than the upper pipe. The thickness of the wall, in the vertical ascending pipeline, the basic structure of the gas-liquid two-phase flow has a fine bubble flow structure, a bullet-like flow structure, a block flow structure, a ring-shaped flow structure with fibers, and an annular flow structure. However, since the volume of condensed water in the wet steam is relatively small, the flow of excess water in the ascending pipe often appears as an annular flow structure, but when the amount of water is particularly large, it also appears as a ring with fibers. Flow structure. Among them, the fibrous fluid is actually a condensed water. Flow in a vertically descending pipe: In a vertically descending pipe, the structure of the gas-liquid two-phase flow is similar to that of a vertically ascending flow, but differs not only in the opposite flow direction but also in the case of the same average flow velocity. The flow rate of the liquid in the vertical drop pipe is much faster than the flow rate of the liquid in the vertical rise pipe.


Vortex flowmeters measure steam. Accurately arrange the steam traps accurately: People have long discovered that when the steam has more water, the vortex flowmeter will have a "leakage pulse" phenomenon, that is, in the case of a stable steam flow rate, the vortex flow It should have a stable pulse output proportional to the flow rate. But sometimes it is found that the output pulse of the meter is inexplicably less. The distribution of the output pulse recorded on the two-dimensional coordinates can also be clearly seen. The pulse that should be approximately evenly distributed is one less at a place. Pulses, in severe cases, are a lot less pulses, and in the worst case, there are no pulses at all. This may be related to the formation of a vortex column by impinging on a large volume of droplets having a non-uniform distribution on the vortex generator.


Vortex flowmeters measure steam. Accurately arrange the traps accurately: The rational placement of the hydrophobic points is critical to adequate hydrophobicity. Wet steam is a two-phase fluid in terms of properties, but in the case of low humidity, Treat it as a single-phase fluid and measure with a general flow meter. Severe steam with water will cause a “leakage pulse” phenomenon in the vortex flowmeter. In more serious cases, the vortex flowmeter will have no pulse output at all. For the case where the steam severely affects the normal measurement of the vortex flowmeter, the usual treatment method is to fully hydrophobic at the appropriate position upstream of the vortex flowmeter. Reasonably arrange the steam trap to make the dryness of the wet steam as high as possible, and ensure the normal measurement of the vortex flowmeter.



Tips: Bo Rui Instrument is a professional manufacturer and seller of instrumentation, which can provide you with electromagnetic flowmeter, vortex flowmeter, turbine flowmeter, throttling device and other flow meters; ultrasonic level gauge, magnetic flap level Meters, radar level gauges and other liquid level meters; pressure transmitters, differential pressure transmitters and other pressure instruments; thermocouples, thermal resistance and other temperature instruments and other products production and sales, international brand instrumentation agents, automation control engineering, etc. Products, welcome new and old customers to visit, Henan Bo Rui Instrument Co., Ltd. with the highest quality and most comprehensive after-sales service, welcome you.
For more exciting information, please see the electromagnetic flowmeter news information of this site. Keywords: vortex flowmeter; electromagnetic flowmeter; turbine flowmeter.
This article Source: http://Henan Bo Rui Instrument Co., Ltd. National Free Service Hotline Sales Hotline
18538000788
Tel
Fax
QQ: 1815002922
Name: Henan Bo Rui Instrument Co., Ltd. Homepage: http://
Email: [email protected]
Zip code: 450045
Address: No. 159, Huayuan Road, Jinshui District, Zhengzhou City, Henan Province
Http://news.chinawj.com.cn Submission:

Hex Bolt

HEX BOLT: One type of fastener, consisting of the head and the rod (cylinder with external full/half threads) and usually uesd together with nut.washer.

According to clients' demands, material can be Stainless Steel SS304/316/316L, Duplex Steel S32750/32760/2205/NAS660/904L..

The Standard is various, main standard is DIN/ANSI/GB, of course we also can accept JIS/BSW

Raw material should be cut in concrete length and processed by Cold/hot forge.surface finish,then can become various size fasteners.

Our Stainless Steel fasteners have great quality and are widely used in Heavy Industry.Shipping Industry.Construction Industry.Chemical Industry and Marine Industry.

Hex Bolt is one of our advantage Products. Chinese Manufacture, Qualified Hardware and Fasteners, Different size/Diameter/Tooth pitch, we all can satiafy your demands.

Hex Bolt DIN933/931

Hex Bolt,Hex Head Bolt,Hex Bolt Fastener,Stainless Steel Hex Bolt

Taizhou Risco Stainless Steel Products Co.,Ltd , https://www.riscofastener.com

Posted on