Vane pump troubleshooting common failure

Vane pump product manuals generally have detailed installation guidelines and precautions. However, in the actual use of the process, often there are still such problems and problems occur, the vast majority of these problems should be caused by improper use, improper use of oil pump damage accounted for up to 95% or more, the real problem is the product quality is Few. In order to distinguish what kind of problem belongs to the correct use and determine the cause of the malfunction, the following experience is provided for reference: First, improper use of several performance: 1, the wrong installation method: a, the coupling is too tight: Shaft and shaft with the gap is too small or no gap, the percussion, the bearing will be injured, leading to early bearing damage and affect the life of the pump. b, Axial axial force: As the coupling is not installed in the axial clearance, the hardware installation will make the bearing and bearing ring damage, will seriously damage the entire pump core. c, coaxial error: If the installation of concentricity exceeds the specified value, the bearing and the entire pump eccentric and early damage, the general control of ≤ 0.1 mm or so as well. 2, bad system environment a, oil is dirty: Because the mailbox is not sealed, the surrounding dust and iron mixed with oil can make early damage to the pump. b, the temperature is too high: the cooling device is not installed, the continuous use of the machine, the oil temperature will continue to rise. If the oil temperature is higher than 70 degrees for a long time, the life of the pump will be greatly shortened, generally it will be damaged (sometimes shorter) in six months to one year. c, oil in water: In a water-cooled device, due to poor water seal, resulting in water into the oil, the pump parts rusty, lock, leaves thrown out and so on. 3, the direction of the rotation port error: a, pump Xiao Zi did not go in Xiao Kong Li (or pull out caused by rotation), which is the pump suction port space reduced, oil absorption resistance poor resistance, manifested as noise Extra large, pressure swing, prolonged use will make the oil temperature rise too fast, the curve of the stator into a corrugated life shortened. b, rotating the seal trimming or screw fastening uneven oil leakage phenomenon. Second, the phenomenon of common failure to determine: 1, research pump (burning plate): Reason: oil is dirty, improper installation, the oil into the water, iron in the oil (the new machine market). High oil temperature or component manufacturing accuracy is not enough. 3, noisy: especially large a. Inlet leakage. (O-ring seal failure, the screw is too long or too thin flanges) b. Clogged filter, into the oil flow is not enough. c. The viscosity of the oil is too high. (The weather is too cold or wrong grade) d. Assembly error. (When changing the location of the import and export direction of the method and the essentials is not properly or the seal is not installed and the pump positioning Shaw not inserted into the back cover of the air to go). Larger a. The above situation is uniform. b. product quality is not good. 3, the system is no pressure: a. Relief valve failure. (To be cleaned or replaced) b. Pressure relief valve malfunction. (Need to be cleaned or replaced) 4, the stator curve was wash plate corrugated: a result of poor suction, the phenomenon is unstable pressure, the pressure is too low, the noise is high, there is a clear metal percussion, and Due to inhalation of air compressed by crackling, for the following reasons: a. Oil too viscous oil shortage. b. Suction filter clogged or too small, oil absorption area is not enough. c. The oil level is too low, the oil is not in place. 4, the system if the pressure exceeds the rated standard will appear the following conditions: a. Shell fracture. b. Stator breakage. c. Shaft rupture. d. The screw is broken. e. Shortened life span. Reasons: Mailbox oil dirty or into the iron after the overflow valve and other functional valve stuck. Will lead to unlimited pressure increase, if the system's "safety protection" design is not reasonable or "safety factor" too low will also lead to instantaneous pressure over the system pressure exceeds the rated standard, the internal components of the pump can not withstand high pressure resulting A part of the rapid decline in the fracture or life expectancy. Check the pressure method: In the pump inlet and outlet port connected pressure gauge, observe the pressure conditions under normal conditions. Third, the pump after serious damage to the technical appraisal: pump damage, we must first check the appearance, internal and related phenomena. When the following phenomena occur, it can determine the corresponding reasons: 1, bearing damage: When the pump more serious damage to damage, as long as there is damage to the bearings, will be regarded as improper installation. (Because the bearing is damaged first, when the bearing is damaged, the shaft will swing, telling the swing will not cause other parts to be damaged) 2. The inner liner is embroidered: When the pump core is seriously damaged, there is only rust in it. Will be regarded as caused by water in the oil. (Because the oil is normal, there will be no rust) 3, poor oil quality: When the pump is seriously damaged. As long as there is stolen oil in the oil, foreign matter or oil has become black, will be treated as dirty oil, caused by poor oil quality. 4, the new shaft rupture: should try to check the location of the fracture, if it is material or heat treatment is not good, its damage point should be the weakest link, that is, the minimum diameter or flower health, if not in the weakest point should be considered as the fracture Improper, coaxial deviation caused by too much. 5, in the inspection of materials, should be the material composition, microstructure, hardness and other inspection, but also on the damaged parts of the order and causal relationship analysis, and ultimately be able to identify the cause. Fourth, the following are several product quality problems: 1, high noise: as long as other reasons are excluded, it should be a quality problem. 2, parts scratched: turn and scratches the side plate is relatively symmetrical, diagonal scratches the phenomenon should be quality problems. 3, the shaft fracture: When broken in the weakest place, while other parts are intact when the shaft is the quality problem. 4, the rotor fracture: the other pieces are not broken, only the rotor off, is a quality problem. 5, leaf fracture: the other pieces are not broken, only leaves off, is the quality problem.

Router Bit / Profiling Wheel

Router Bit,Profiling Wheel,Diamond Router Bit

Diamond Segment,Diamond Saw Blade Co., Ltd. , http://www.cndiamondsawblade.com

Posted on